![]() Click Schematic tab Other Tools panel Symbol Builder drop-down Symbol Builder.In this example, you take geometry (either geometry you just drew, existing geometry, or a vendor representation) and convert it to an AutoCAD Electrical panel footprint using the Symbol Builder. The first four or five characters of the block name for a panel symbol is not as critical as it is for schematic symbols. The symbol block naming for the panel footprint does not follow the special naming convention.A panel symbol must have the P_TAG1 or P_TAGSTRIP attribute rather than the TAG1 or TAGSTRIP attribute. Some of the attribute names are different.There are no parent/child versions of a symbol for panel footprint symbols.Panel footprint symbols do not have to carry the wire connection attributes that schematic symbols almost always carry. ![]() The procedure for creating a panel footprint is like that of creating a schematic symbol with the following differences: ![]() ![]() A panel footprint symbol can be in either of two general forms: a to-scale physical representation of the device or a generic wiring diagram representation whose main purpose is to show wire connection annotation information. ![]()